ChemicalBook >>Methyl 3-methoxypropionate>>Methyl 3-methoxypropionate(3852-09-3)

Methyl 3-methoxypropionate(3852-09-3)

Methyl 3-methoxypropionate(3852-09-3)
Product IdentificationBack to Contents
【Product Name】

Methyl 3-methoxypropionate
【Synonyms】

Methyl 3-methoxypropanoate
【CAS】

3852-09-3
【Formula】

C5H10O3
【Molecular Weight】

118.13
【EINECS】

223-358-1
【RTECS】

UF5274000
【RTECS Class】

Other
【Beilstein/Gmelin】

1744829
【Beilstein Reference】

4-03-00-00693
Physical and Chemical PropertiesBack to Contents
【Boiling Point】

142-143
【Density】

1.009 g/cm3 (20 C)
【Refractive Index】

1.40 (20 C)
First Aid MeasuresBack to Contents
【Ingestion】

Seek medical assistance.
【Inhalation】

Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
【Skin】

Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
【Eyes】

Flush with running water for at least 20 minutes.
Hazards IdentificationBack to Contents
【Inhalation】

May cause irritation or burns.
【Skin】

See Inhalation.
【Eyes】

See Inhalation.
【Hazards】

Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
【EC Risk Phrase】

R 10 36/37/38
【EC Safety Phrase】

S 26 36/37/39
【UN (DOT)】

3272
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Wear appropriate protective gloves, clothing and goggles.
【Respirators】

Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting MeasuresBack to Contents
【Flash Point】

47
【Fire Fighting】

Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
【Fire Potential】

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.
Transport InformationBack to Contents
【UN Number】

3272
Stability and ReactivityBack to Contents
【Combustion Products】

Fire may produce irritating, corrosive and/or toxic gases.
Company Name: Tongchuang Pharma(Suzhou). Co., Ltd.
Tel: 0512-63263366 18912765016
Fax: 0512-6326 3366
WebSite: http://www.hezefdc.com/ShowSupplierProductsList15406/0_EN.htm
Company Name: Jinan Hongjia Chemical Co., Ltd
Tel: 15253128188
Fax:
WebSite:
Company Name: ANDA CHEM TECH CO., LTD.
Tel: 13280681246
Fax:
WebSite: www.sdadhg.com/
Company Name: Shandong Hima Supply chain Management Co., LTD
Tel: 0533-13011607593; 13011607593
Fax:
WebSite: http://www.hezefdc.com/supplier/25747908/
Company Name: Hubei Shishun Biotechnology Co. Ltd
Tel: 027-59223025 15107168801
Fax: 027-59223025
WebSite: www.ss-bio.com/
Company Name: J & K SCIENTIFIC LTD.
Tel: 18210857532 18210857532
Fax: 86-10-82849933
WebSite: www.jkchemical.com
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006356688 18621169109
Fax: 86-21-61259102
WebSite: www.x-labseek.com/
Company Name: TCI (Shanghai) Development Co., Ltd.
Tel: 021-67121386
Fax: 021-67121385
WebSite: https://www.tcichemicals.com/CN/zh/