| HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
| FIRE | 1 | Materials that require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur. Includes some finely divided suspended solids that do not require heating before ignition can occur. Flash point at or above 93.3 °C (200 °F). (e.g. mineral oil, ammonia) | |
| REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
| SPEC. HAZ. |
| Chemical Name | ACGIH TLV | OSHA PEL | NIOSH IDLH |
|---|---|---|---|
| Acetonitrile 75-05-8 | TWA: 20 ppm S* | TWA: 40 ppm TWA: 70 mg/m3 TWA: 5 mg/m3 CN (vacated) TWA: 40 ppm (vacated) TWA: 70 mg/m3 (vacated) TWA: 5 mg/m3 (vacated) STEL: 60 ppm (vacated) STEL: 105 mg/m3 S* | IDLH: 500 ppm IDLH: 25 mg/m3 CN TWA: 20 ppm TWA: 34 mg/m3 |
| Chemical Name | Algae/aquatic plants | Fish | Toxicity to Microorganisms | Crustacea |
|---|---|---|---|---|
| Acetonitrile 75-05-8 | - | 1600 - 1690: 96 h Pimephales promelas mg/L LC50 flow-through 1650: 96 h Poecilia reticulata mg/L LC50 static 1850: 96 h Lepomis macrochirus mg/L LC50 static 1000: 96 h Pimephales promelas mg/L LC50 static | - | 5838: 18 h Daphnia pulex mg/L EC50 |
| Chemical Name | California Hazardous Waste Status |
|---|---|
| Acetonitrile 75-05-8 | Toxic Ignitable |
| Chemical name | TSCA | DSL | NDSL | EINECS | ELINCS | ENCS | IECSC | KECL | PICCS | AICS |
|---|---|---|---|---|---|---|---|---|---|---|
| Acetonitrile | X | X | - | X | - | X | X | X | X | X |
| 2,3,4,5-Tetrachloroaniline | - | - | - | X | - | - | - | - | - | - |
| Chemical Name | CWA - Reportable Quantities | CWA - Toxic Pollutants | CWA - Priority Pollutants | CWA - Hazardous Substances |
|---|---|---|---|---|
| Acetonitrile 75-05-8 | X | X |
| Chemical Name | New Jersey | Massachusetts | Pennsylvania |
|---|---|---|---|
| Acetonitrile 75-05-8 | X | X | X |
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.